Kenwood TKR-750 Programming Reference Manual page 58

Hide thumbs Also See for TKR-750:
Table of Contents

Advertisement

6 EDIT MENU
Table 6-7 Assigning Functions to the Auxiliary Output Ports
Function Name
None
Not perform any operation.
The PF [COR] output port is activated when
COR
receiving the signal.
The PF [Fan Status] output port is activated
Fan Status
when the fan starts operating.
The PF [Power Supply Lower Level] output
Power Supply
port is activated when the power voltage is
Lower Limit *1
decreased.
The PF [RF Power Down Detect] output port
RF Power Down
is activated when the transmission power
Detect *2
becomes lower than the configured threshold
level.
The PF [RX Signal Detect] output port is
Reception Signal
activated when the RSSI voltage is
(Below) *1
decreased.
Reception
The PF [RX Unlock] output port is activated
Unlock
when RX PLL is unlocked.
Toggle the PF [Selectable] output port
between Active/Inactive when the signal is
Selectable
applied to the Auxiliary Input port or the PF
key.
The PF [TOR] output port is activated when
the signalling matches while receiving the
signal.
TOR
The PF [TOR] output port is activated on the
channel without the signalling configuration
while receiving.
The PF [TXS] output port is activated while
TXS
transmitting.
Transmission
The PF [TX Unlock] output port is activated
Unlock
when the TX PLL is unlocked.
*1: It can configure the any voltage value to detect the voltage
decrease/increase.
(Refer to 6.4.1 Optional Features 1 Tab.)
*2: It can select High Power or Low Power with "Power Down
Detect" in Tuning mode. This function notifies the user that the
transmission power is suddenly decreased when the power is
decreased, etc. However, you cannot use this function as a real-
time power monitor.
(Refer to 7.3.11 Tuning Mode.)
Default: Hi (25 W) power: Approximately 10 W
Low (1 W) power: Approximately 0.3 W
Note:
! When configuring the Activation code to the PF [COR]
output port or the PF [TOR] output port, TKR-750/850/751/
851 cannot activate the repeat operation since it sends the
code while it is in Busy status, so that it cannot receive the
Air Remote code and the Repeater Open code.
6.10.2 AUX Tab.)
! Since the status of Air Remote Encode is retained while
transmitting using Repeater PTT, Local Mic PTT, or External
PTT, or CW ID, TKR-750/850/751/851 cannot send the
Activation code even when the function is activated while the
Activation code is configured to the PF [Power Supply Lower
Limit] output port. In this case, it transmits the Activation code
after ending the transmission (the function deactivates). When
the Deactivation code is configured to the port, it sends the
Deactivation code after transmitting the Activation code.
to 6.10.2 AUX Tab.)
53
Description
(Refer to
(Refer
Field Programming Reference (FPRG)
" Logic Type (AUX Output)
It can select the status of the signal (Low/High) to
activate or deactivate the function with the Air Remote
code. You can configure this function only when at
least one function is assign to "Function". Select
"Active Low" or "Active High" from the dropdown list.
The assigned function activates in
Active Low
Active Low.
Range
The assigned function activates in
Active High
Active High.
Default Active Low