6.11 Multi-table Window

It can configure the QT/DQT (Current) code on this
window. When the Multi-table function is enabled, it can
wait for the call with two types of QT/DQT code; Primary
and Current.
(Refer to 6.1.6 Multi-table, 6.2.9 Multi-table
(Channel Edit).)
This window consists of "Main-table" and "Sub-table" tabs
and it can switch the window by clicking the tabs.

6.11.1 Decode (Multi-table)

It can configure the signalling used to receive the calls.
Select the QT tone or DQT code from the dropdown list or
directly enter the QT tone and the DQT code.
# Selecting the QT/DQT Encode Code from the
Dropdown List:
QT
Range
DQT Normal
DQT Inverse D023I - D754I
Default
None
# Directly entering the QT/DQT Encode Code:
QT
Range
DQT Normal
DQT Inverse D000I - D777I
QT
In steps of
DQT
Default
None
Note:
! It cannot configure the QT/DQT code to the No.1 table.
! It can use numbers, "D", "N", "I", ".", and "," for the 5 digits of the
QT/DQT Encode code.
! When entering only numbers, the code is configured as QT
Tone.
! When entering "D" as the first character of the code, the code is
configured as the DQT code.
! When entering the value, which is out of the range, it will be
automatically replaced with the highest value or the lowest value
in the range.

6.11.2 Encode (Multi-table)

It can configure the signalling used to transmit.
Select the QT tone or DQT code with the dropdown list or
directly enter the QT tone and the DQT code.
Version: 1.01
67.0 - 250.3 Hz
D023N - D754N
67.0 - 254.1 Hz
D000N - D777N
0.1 Hz
1
Field Programming Reference (FPRG)
# When Selecting the QT/DQT Encode Code with the
Dropdown List:
QT
Range
DQT Normal
DQT Inverse D023I - D754I
Default
None
# Directly entering the QT/DQT Encode Code:
QT
Range
DQT Normal
DQT Inverse D000I - D777I
QT
In steps of
DQT
Default
None
Note:
! It cannot configure "Encode" if the "Decode" function is not
configured.
! It can use numbers, "D", "N", "I", ".", and "," for the 5 digits of the
QT/DQT Encode code.
! When entering only numbers, the code is configured as QT
Tone.
! When entering "D" as the first character of the code, the code is
configured as the DQT code.
! When entering the value, which is out of the range, it will be
automatically replaced with the highest value or the lowest value
in the range.
6 EDIT MENU
67.0 - 250.3 Hz
D023N - D754N
67.0 - 254.1 Hz
D000N - D777N
0.1 Hz
1