Error messages
5.2 Errors from the communications module/reader
Error mes-
Description
sage
(hex)
0xE5FE0B
Incorrect sequence of acknowledgement frames (TDB / DBN)
0xE5FE0C
Synchronization error (incorrect increment of AC_H / AC_L and CC_H / CC_L in the cyclic control word).
"INIT" had to be executed
0xE6FE01
Unknown command
Ident profile is sending an uninterpretable command to the communications module.
The transponder has signaled an address error.
0xE6FE02
Invalid command index CI
0xE6FE03
Bad parameter assignment of the communications module or reader
Check "INPUT" parameter in the Ident profile.
Check the parameter assignment in RSLogix.
"WRITE-CONFIG" command has incorrect parameter settings.
After a startup, the reader or communications module has still not received an INIT".
The parameter assignment of the reader or communications module on PROFIBUS/PROFINET was
incorrect and the command cannot be executed.
Length of the input/output areas too small for the cyclic I/O word.
Correct GSD file being used?
User data length set with command (e.g. "READ") too high.
Error when processing the command
Reader/communications module hardware defective: The reader or communications module re-
ceives bad data with "INIT".
AB byte does not comply with the useful data length.
Wrong reset instruction was selected
Regardless of the selected reader system, use the "Reset_Reader" instruction.
0xE6FE04
Presence error:
A transponder has passed by a reader without being processed by a command.
This error message is not reported immediately. Instead, the reader or communications module is
waiting for the next command (read, write). This command is immediately replied to with this error. This
means that a read or write command is not processed. The next command is executed normally again
by the reader/communications module.
An "INIT" from the Ident profile also resets this error status.
Bit 2 is set in the OPT1 parameter and there is no transponder in the transmission window.
0xE6FE05
An error has occurred that makes a Reset_Reader ("WRITE-CONFIG" with "Config = 3") necessary.
The "WRITE-CONFIG" command is incorrect.
Start "INIT" after correcting the error
Check the "IID_HW_CONNECT" parameter.
0xE6FE06
The reset timer has expired.
0xE6FE81
Reserved
0xE6FE82
Reserved
0xE6FE83
Reserved
0xE6FE84
Reserved
108
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03