Transponder addressing
Addressing
Addressing of the transponders is linear from address "0x0000" (or the specified start
address) to the end address. The CM or reader automatically recognizes the size of the
memory on the transponder. If the end address on the transponder is exceeded, you receive
an error message.
The next table shows the address space of the individual transponder parameters. The
"ADDR_TAG" and "LEN_DATA" parameters must be assigned according to this address
space.
Address space of the transponder/MDS variants according to ISO 15693 for RF200, RF300
System
RF200,
RF300
96
Addressing
Start address
End address
ID-Nr.: (fixed-coded, can only be read as a whole)
Start address
Length
Start address
End address
ID-Nr.: (fixed-coded, can only be read as a whole)
Start address
Length
Start address
End address
ID-Nr.: (fixed-coded, can only be read as a whole)
Start address
Length
ISO MDS (my-d SRF55V10P; 992 bytes)
Start address
End address
ID-Nr.: (fixed-coded, can only be read as a whole)
Start address
Length
Start address
End address
ID-Nr.: (fixed-coded, can only be read as a whole)
MDS D139 (I-Code 1; 44 bytes)
ISO-MDS (I-Code SLI; 112 bytes)
ISO MDS (Tag-it HF-I; 256 bytes)
ISO-MDS (MB 89R118B, 2000 bytes)
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
16-bit hexadecimal number
0x0000
0x002B
0xFFF0
0x0008
0x0000
0x006F
0xFFF0
0x0008
0x0000
0x00FF
0xFFF0
0x0008
0x0000
0x03DF
0xFFF0
0x0008
0x0000
0x07CF