The "PHYSICAL-READ" command
The "PHYSICAL-READ" command is used for the following functions:
● Reading codes
● Follow-on command after "activate read program number" for reading out the program
number
● Follow-on command after "activate read match string" for reading out the match string
Table 4- 79
PHYSICAL-READ
CMD
OFFSET
ADDR_TA
BUFFER
G
0x70
Offset in
0x0000
the
"RXREF"
send
buffer
4.6.4.5

Effect of the commands

The commands used take effect as follows:
● The input parameters "INIT" and "RESET" interrupt command execution within the
communications module.
● The completed message that follows the "INIT" or "SRESET" ("DONE" or "ERROR")
always relates to the input parameter "INIT" or "SRESET" and not to the interrupted
command.
● The input parameter "INIT" resets communication between the Ident profile and the
communications module. Following "hard" resetting of the communications module, the
Ident profile automatically transfers the "WRITE-CONFIG" command to the
communications module. This is why it is absolutely necessary that you store the
"WRITE-CONFIG" command in the first element of the command buffer "CMDREF".
● The "WRITE-CONFIG" command resets all functions within the communications module,
with the exception of the communication.
● The parameter "SRESET" interrupts a running command.
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
LEN_DATA
Length of the data to be fetched from
the reader:
≥ code length +2
= 0x01
≥ Match string length +2
Configuring the instructions
4.6 Programming the Ident profile
RXREF
Data fetched from the reader:
Code data
Program number
Match string