Table 4- 73
Address
0x0000
0x0001
0x0002
0x0003
...
n + 2
n + 3
Table 4- 74
Address
0x0000
Table 4- 75
Address
0x0000
Table 4- 76
Address
0x0000
Table 4- 77
Address
0x0000
0x0001
0x0002
...
0xN
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
Command data area "TXREF" command identifier 0x03 (write match string)
Value
0x03
0x00...0xFF
0x00...0xFF
--
...
--
--
Command data area "TXREF" command identifier 0x04 (activate read match string)
Value
0x04
Command data area "TXREF" command identifier 0x05 (set DISA bit)
Value
0x05
Command data area "TXREF" command identifier 0x06 (reset DISA bit)
Value
0x06
Command data area "TXREF" command identifier 0x07 (XMATCH)
Value
0x07
0x00
You will find detailed information in
the manual "SIMATIC MV420 /
SIMATIC MV440" or "SIMATIC
MV500".
Configuring the instructions
4.6 Programming the Ident profile
Meaning
Command identifier "Write match string"
Match string length high byte
Match string length low byte
1st character of the match string
...
(n-1)th character of the match string
nth character of the match string
Meaning
Command identifier "Read match string"
Meaning
Command identifier "Set DISA bit"
Meaning
Command identifier "Reset DISA bit"
Meaning
Command identifier "XMATCH"
Reserved
XMATCH user data