Configuring the instructions
4.6 Programming the Ident profile
Table 4- 56
Parameter
CMD
OFFSETBUFFER
LEN_DATA
TXREF
Table 4- 57
Put_SET_ANT
Mode
Length
Put_END
UID
Mode
Length
76
PUT (not with RF68xR)
Value / description
0x65
Offset in the "TXREF" send buffer
Length of the parameter data to be sent
Parameter data to be written
Data structure of the PUT command
Switches the antenna of the reader off and on.
RF200/RF300:
0x01 ≙ antenna on
0x02 ≙ antenna off
RF600:
Bit 0 ≙ ANT 1 / internal antenna (1 = on)
Bit 1 ≙ ANT 2 / external antenna (1 = on)
Bit 4 ≙ TagList (0 = initialize, 1 = continue working with the existing list)
3
Terminates communication with a transponder (MOBY U only).
UID of the transponder
0x00 ≙ end processing of the transponder
0x01 ≙ processing pause of the transponder
11
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03