Siemens SIMATIC Ident Function Manual page 52

Rfid systems. ident profile, add-on instruction for rockwell systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Configuring the instructions
4.5 Programming add-on instructions
Table 4- 36
ATTRIBUTE "0x85" ("IID_TAG_STATUS_85_RF600" data type)
Name
status info
antenna
channel
UID
DT_glimpsed_1
DT_glimpsed_2
DT_glimpsed_3
DT_glimpsed_4
reserved1
reserved2
reserved3
reserved4
last observed hour
last_observed_min
last_observed_sec
last observed EPC length
EPC ID Byte
reads HB
reads LB
RSSI
mean RSSI
max RSSI
min RSSI
min POWER
current_POWER
reserved5
The internal time stamp of the reader that relates to this event is output. The internal reader time stamp is not synchro-
1)
nized with UTC.
The "Reads" value indicates the total transponder recognitions (inventories) regardless of the set Smoothing parame-
2)
ters. In this way, in extreme situations, the "Reads" counter can reach extremely high values without the transponder
ever reaching the "Observed" status.
The "current_Power" value is specified as transmit power in 0.25 dBm steps (ERP/EIRP). A "current_Power" value of
3)
"72" (0x48) therefore corresponds to 18 dBm (ERP/EIRP).
You will find more detailed information on the individual status modes in the manuals
matching the modes "FB 45", "FB55" and "SIMATIC RF620R/RF630R".
The identifiers of the status modes correspond to the following identifiers in the other
manuals:
0x04
0x82
0x83
0x84
0x85
52
Type
Comment
SINT
MDS status mode
SINT
Antenna which has observed the MDS
SINT
Channel
SINT[8]
SINT
Time elasped between acknowledgement and first read in
[ms]1 Highbyte
SINT
Time elasped between acknowledgement and first read in
[ms]2
SINT
Time elasped between acknowledgement and first read in
[ms]3
SINT
Time elasped between acknowledgement and first read in
[ms]4 Low-Byte
SINT
SINT
SINT
SINT
SINT
Last observed time hour
SINT
Last observed time minutes
SINT
Last observed time seconds
SINT
Last observed time EPC length
SINT[62]
EPC-ID
SINT
Number of Reads of MDS in Inventory (1 - 65535)
SINT
Number of Reads of MDS in Inventory (1 - 65535)
SINT
Current RSSI value of MDS
SINT
Mean RSSI value of MDS
SINT
Max RSSI value of MDS
SINT
Min RSSI value of MDS
SINT
Min Power value of MDS
SINT
Current Power value of MDS
SINT[137]
0x01
0x02
0x03
0x04
0x05
1)
1)
2)
3)
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03