Siemens 6GK1 901-1GB01 System Manual page 10

Passive network components. industrial ethernet / profinet
Table of Contents

Advertisement

Instructions for fitting connectors, attachments and devices
2.2 Industrial Ethernet FastConnect Stripping Tool
6. Clamp the stripping tool as far as it
will go.
9. After releasing the tool, remove the
remnants of the cable from the tool.
12. Pull the protective foil off the wires.
10
7. To strip the insulation, turn the tool
in the direction of the arrow
approx. 4 times for PVC
insulation
approx. 8 times for PUR
insulation
10. If the white filler is not removed with
the insulation, remove it with your
hand.
13. When assembling the cable, follow
the installation instructions supplied
with your connector or outlet.
8. Keeping the it closed, pull the
stripping tool with jacket and
remnants of the shield off the end of
the cable.
If the cutting result is poor, change
the knife cassette.
11. The protective foil is easier to
remove if you score it between the
wires with a screwdriver.
14. Replace the knife cassette after
approx:
1500 operations on cables with
PVC outer jackets
150 operations on cables with
PUR outer jackets
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01