Instructions for fitting connectors, attachments and devices
2.3 Electrical networks
2. Cut the braided shield approximately 10 mm from the edge of the outer sheath
3. Shorten the white-blue pair by approximately 3 mm to 32 mm
4. Wrap copper band around the braided shield.
52
and pull off the loose shield.
(to introduce the cable as shown in Figure 1–10).
– Turn back the braided shield over the outer sheath.
– Unwind the aluminum foil shield leaving approximately 15 mm (shorter pair) or
approximately 18 mm (longer pair) to the folded back braided shield and cut off the
unwound shield.
– Remove the plastic foil and blind element.
– Remove approximately 5 mm of the insulation from the conductors.