Figure 2-6
Energy connector - fitting
Fitting connectors to cables
1. Push the clamping screw (a), pinch ring (b) and sealing ring (c) over the cable.
2. Strip the jacket and wires as shown in the drawing.
3. Fit the 0.75 mm² wire-end ferrules to the stranded wires.
4. Push the connector sleeve (d) over the wires.
5. Screw the wires into the screw terminals of the female or male connector insert as shown
6. Push the connector sleeve (d) onto the female or male insert (e) and screw the two parts
7. Push the pinch ring (b) over the sealing ring (c) and press the two parts together with the
8. Screw the pressure nut tight.
Pin assignment
View of the connector
face
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01
in the chart.
together.
pressure nut (a) into the connector sleeve.
Pin
(6GK1905-0EA00)
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Instructions for fitting connectors, attachments and devices