9. Cut back the Kevlar with the Kevlar
scissors leaving 5 mm.
13. Cut into the buffer with pliers
opening ø 0.3 mm and pull off the
buffer without skewing.
Approximately 5 mm of the buffer
remain.
16. Turn the "Clamp" (1) wheel to
"Open" and the "Cleave" (2) wheel
to the "0" setting.
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01
Instructions for fitting connectors, attachments and devices
10. Push the anti-kink sleeve over the
fiber and the core jacket.
14. Push the connector body with the
ferrule on to the fiber.
17. Feed the fiber into the cleave tool
and lock the plug. The fiber projects
through the clamp wheel.
2.4 Optical networks
11. Push the buffer and Kevlar clamp
onto the fiber as far as the core
sleeve.
12. Feed the Kevlar yarn through the
opening.
15. Screw the connector body and
union nut together.
18. Turn the "Clamp" wheel gently
towards the "Lock" direction to
clamp the fiber.