Fitting The Ie Fc Rj-45 Modular Outlet; Connecting The Rj-45 Modular Outlet - Siemens 6GK1 901-1GB01 System Manual

Passive network components. industrial ethernet / profinet
Table of Contents

Advertisement

2.3.10

Fitting the IE FC RJ-45 modular outlet

2.3.10.1

Connecting the RJ-45 Modular Outlet

Introduction
Below, you will see the individual steps in connecting the RJ-45 modular outlet.
Procedure
The modular outlet consists of the
following:
a: Insert
b: Base module
3. Lift up the cover of the IE FC RJ-45
modular outlet.
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01
Instructions for fitting connectors, attachments and devices
1. Remove the locking screw of the
insert.
Pull the insert forward as far as the
limit stop.
4. Insert the wires into the contact
element of the FC RJ-45 modular
outlet as far as the limit stop
according to the color markings.
2.3 Electrical networks
2. Now release the two cover screws
that are now accessible.
5. Secure the wires in position by
pressing down the terminals as far
as the limit stop.
While doing this, make sure the
wires remain in the guide slits.
39