Siemens 6GK1 901-1GB01 System Manual page 22

Passive network components. industrial ethernet / profinet
Table of Contents

Advertisement

Instructions for fitting connectors, attachments and devices
2.3 Electrical networks
Procedure
1. In the stripping tool, use the green
knife cassette (5.1 mm).
If necessary, adjust the cutting dept
the
knife cassette using the middle
soc
ket-head screw.
6. To strip the insulation, turn the tool
in the direction of the arrow
approx. 4 times for PVC
insulation
approx. 8 times for PUR
insulation
22
2. Take the stripping tool in your right
hand.
h of
3. Measure the cable length against
the measuring template. Use your
left index finger as the limit stop.
Note: If the stripping tool has an older
measuring template, add the new
measure (38 mm from the edge of the
stripping tool).
7. Keeping the it closed, pull the
stripping tool with jacket and
remnants of the shield off the end of
the cable.
Note: If a core is damaged, the section
of cable must be cut off and stripped
again.
4. Place the cable in the stripping tool.
The index finger of your left hand is
the limit stop.
5. Tighten the stripping tool.
8. Remove any remaining white filler
with your fingers.
9. Cut off the inner cable spacer as
close to the shield braid as
possible. Also shorten the cable
spacer between the two pairs
orange/orange-white, green/green-
white, and blue/blue-white,
brown/brown-white.
Passive network components
System Manual, 02/2013, C79000-G8976-C282-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6gk1 901-1ga006gk1 901-1gb00

Table of Contents