Chapter 2 Configuring and Upgrading the System
5.3.3 Replacing 2.5-inch Hard Disk Drive
Follow the procedure below to remove the failed hard disk drive. The hard disk drive is replaced with new device
with the server powered on.
(1)
Replacing the Hard Disk Drive
1.
Locate the failed hard disk drive.
When a hard disk drive fails, the DISK ACCESS LED on the hard disk drive's handle lights amber.
2.
Remove the failed hard disk referring to Chapter 2 (2.4 Replacing a hard disk drive) and Chapter 2
(5.3.2 Removing 2.5-inch Hard Disk Drive).
3.
Refer to the steps in Chapter 2 (5.3.1 Installing 2.5-inch Hard Disk Drive) to install a new hard disk
drive.
4.
Restore the redundant configuration.
Refer to Chapter 2 (2.4 Replacing a hard disk drive).
•
Important
Refer to Chapter 2 (5.1.2 Anti-static measures) and Chapter 2 (5.1.4 Preparing
your system for upgrade) before starting installing or removing options.
•
You can replace a hard disk drive during continuous operation.
Note
•
The hard disk drive to be installed for replaced must have the same specifications as
its mirroring hard disk drive.
•
Use unsigned hard disk drive for replacement. To use the signed disk, it is necessary
to recover the duplex configuration by referring to Chapter 2 (2. Disk Operations) after
formatting the disk physically.
As to physical format, refer to Chapter 3 (3. SAS Configuration Utility).
Express5800/R320c-E4, R320c-M4 Maintenance Guide (VMware)
5. Installing Optional Devices
115