Siemens SINUMERIK 840 User Manual page 110

Hide thumbs Also See for SINUMERIK 840:
Table of Contents

Advertisement

4 Measuring Cycles for Turning Machines
4.3.4 L974 2-point measurement on diameter
The following diameters must be defined prior to call:
Parameters
Description
R08
Extended T address (see Section 2.2)
R09
T number (tool number) (see Section 2.2)
R10 = 0
No automatic tool offset
> 0
Automatic tool offset (see Section 2.2)
R11 = 0
Without empirical and average value
> 0
Empirical value memory No./average value memory No. (see Section 2.3)
R18
Protection zone around workpiece ordinate (radius)
R19
Protection zone around workpiece abscissa
R22
Probe number (see Section 2.6)
R23 = 23
2-point measurement on diameter (for outside measurement with
R18/R19; for inside measurement without R18/R19)
= 24
2-point measurement on diameter (for inside measurement only:
with R18/R19)
R25
Variable measuring speed in mm/min
R25=0
Standard cycle value
R27 = 1...R
Number of measurements at same location (typically 1...3)
max
R28 = 1...R
Multiplication factor for measurement path "2a"
max
R29 = 1...R
Weighting factor k for averaging (typically 1...3)
max
R30 = 1...3
Number of measuring axis (see Section 2.12)
R33
Zero offset range
R34
Average value compensation
R36
Safe area
R37
Dimensional difference check
R40
Upper tolerance limit
R41
Lower tolerance limit
R42
Set value
See Section 10.2 for result display parameters
4–36
(according to drawing)
(according to drawing)
(according to drawing)
©
Siemens AG 1990 All Rights Reserved
SINUMERIK 840/850/880 (BN)
07.90
6FC5197- AB70

Hide quick links:

Advertisement

Table of Contents
loading