Siemens SINUMERIK 840 User Manual page 213

Hide thumbs Also See for SINUMERIK 840:
Table of Contents

Advertisement

01.93
7. As soon as the probe gives a signal the traversing axis (measuring axis) is
stopped. The workpiece actual value and the workpiece zero offset are
calculated.
The derived actual value is displayed (actual value).
The dialog text MEASURING ACTIVE is deleted and the STORE softkey is
enabled.
JOG
Workpiece measurement
Tool offset
Workpiece probe
Emp. value memory no.
Setpoint
200.000
Actual value
200.235
Actual position
X
0.000
Y
0.000
Z
0.000
A1
0.000
B1
0.000
STORE
Display after workpiece probe has been retracted
8. When you press the STORE softkey the determined ZO value is stored in
STORE
the selected zero offset memory (fine).
After the value has been stored, the standard input display zero offset of the
previously entered group is entered. The dialog text RETRACT MEASURING
PROBE appears.
Special case:
If G53 is entered (into the input display before the measuring is started),
neither is the zero offset value stored nor the zero offset input display called
up, but the input display "MEASURE WORKPIECE" is displayed directly.
©
Siemens AG 1990 All Rights Reserved
SINUMERIK 840/850/880 (BN)
7 Measuring in JOG Mode (SINUMERIK 880/880 GA2)
D 2
Axis name
L1
1
Axis name
L2
10
ZO (fine)
Empirical value
REPOS offset
X
0.000
Y
0.000
Z
0.000
A1
0.000
B1
0.000
6FC5197- AB70
7.2.1 Operating and function sequence
X
Z
G57
0.025
1. 1
7–13