Checking The Hydraulic-Fluid Level - Toro Groundsmaster 3300 Series Operator's Manual

All-wheel drive traction unit
Hide thumbs Also See for Groundsmaster 3300 Series:
Table of Contents

Advertisement

High Viscosity Index/Low Pour Point
Anti-wear Hydraulic Fluid, ISO VG 46 (cont'd.)
Viscosity Index ASTM D2270
Pour Point, ASTM D97
Industry Specifications:
Note:
Many hydraulic fluids are almost colorless,
making it difficult to spot leaks. A red dye additive
for the hydraulic fluid is available in 20 ml (2/3 fl oz)
bottles. A bottle is sufficient for 15 to 22 L (4 to 6 US
gallons) of hydraulic fluid. Order Part No. 44-2500
from your authorized Toro distributor.
Checking the
Hydraulic-Fluid Level
Service Interval: Before each use or daily
1.
Park the machine on a level surface, lower the
cutting unit, engage the parking brake, shut off
the engine, and remove the key.
2.
Remove the plug from the hydraulic tank
72).
140 or higher
-37°C to -45° C (-34°
F to -49° F)
Eaton Vickers 694 (I-286-S,
M-2950-S/35VQ25 or
M-2952-S)
Figure 72
3.
Remove the dipstick from the hydraulic tank and
wipe it with a clean cloth
4.
Insert the dipstick into the hydraulic tank.
5.
Remove the dipstick and check the fluid level
(Figure
If you have a cutting unit equipped: The
hydraulic-fluid level is at the appropriate level
when the fluid appears between the lower 2
marks on the dipstick (A in
also acceptable for the fluid level to be above
the lower marks.
If you have the auxiliary hydraulic kit
equipped: The hydraulic-fluid level is at
the appropriate level when the fluid appears
between the upper 2 marks on the dipstick
(B in
(Figure
6.
If the fluid level is below the appropriate lower
mark (per your equipped attachment; refer
to step 5) on the dipstick, add the specified
hydraulic fluid into the tank. Repeat steps
through
the appropriate 2 marks on the dipstick.
7.
Insert the dipstick and plug into the hydraulic
tank.
8.
Hand-tighten the plug.
Important:
plug.
9.
Check all hydraulic hoses and fittings for leaks.
g285821
58
(Figure
73).
Figure
73).
Figure 73
5
until the fluid level appears between
Do not use a tool to tighten the
72).
Figure