R1: Referencing
10.5 Referencing with incremental measurement systems
10.5.4
Phase 1: Traversing to the reference cam
Phase 1: Graphic representation
Figure 10-3
Phase 1: Traversing to the reference cam
Phase 1: Start
To start the reference point approach, see Sections "Axisspecific referencing (Page 292)" and
"Axisspecific referencing (Page 292)".
Phase 1: Sequence
In Phase 1, depending on the position of the machine axis with reference to the reference cam,
we distinguish between three cases:
1. The machine axis is positioned before the reference cam
2. The machine axis is positioned on the reference cam
3. The machine axis has no reference cam
300
Axes and spindles
Function Manual, 06/2019, A5E47437747B AA