Table 5-50. DERROR Status Codes (continued)
Description
The drive has entered the Head Alignment Critical state.
The maximum total (AC+DC) head alignment correction limit was exceeded.
Reserved
DSP failed to complete a Read Track Number command in allotted time.
DSP failed to complete a Spin Down command in allotted time.
Reserved.
DSP failed to complete a Spin Up command in allotted time.
DSP failed to complete a Recalibrate command in allotted time.
DSP failed to complete an Introduce Tracking Offset command in allotted time.
DSP failed to complete a Seek command in allotted time.
DSP failed to complete a Measure Alignment Band command in allotted time.
Reserved.
HDA EEPROM test byte is not 55H.
HDA EEPROM checksum result not equal to 00.
PCA EEPROM test byte is not 55H.
PCA EEPROM checksum result not equal to 00.
Computed read/write setting is out of range.
Reserved.
The long term DSP command completed with Alert signal set in status register.
The DSP Alert signal was set when attempting to send a command to the DSP.
Request Status logged a Servo Fault from the fault register.
DSP failure code indicates other than Reset at power-on.
Reserved.
Reserved.
Maximum DC head alignment correction capability was exceeded.
Maximum AC head alignment correction capability was exceeded.
Maximum iteration limit was exceeded in calibrating the NPES gain.