In R mode
■Un\G0 to Un\G399
Address
Address
(decimal)
(hexadecimal)
0
0H
1
1H
2
2H
3
3H
4 to 19
4H to 13H
20 to 35
14H to 23H
36
24H
37
25H
38
26H
39
27H
40
28H
41
29H
42
2AH
43 to 60
2BH to 3CH
61
3DH
62 to 89
3EH to 59H
90
5AH
91
5BH
92
5CH
93
5DH
94
5EH
95
5FH
96
60H
97
61H
98
62H
99
63H
100 to 123
64H to 7BH
124 to 139
7CH to 8BH
140 to 155
8CH to 9BH
156 to 171
9CH to ABH
172 to 199
ACH to C7H
200 to 215
C8H to D7H
216 to 231
D8H to E7H
232 to 247
E8H to F7H
248 to 263
F8H to 107H
264 to 279
108H to 117H
280 to 295
118H to 127H
296, 297
128H, 129H
298
12AH
299 to 302
12BH to 12EH
303
12FH
304 to 399
130H to 18FH
*1 [n] in the table indicates an interrupt setting number. (n = 1 to 16)
*2 For the RTD input module, this area corresponds to System area.
APPX
100
Appendix 3 Buffer Memory Areas
Name
Latest error code
Latest address of error history
Latest alarm code
Latest address of alarm history
*1
Interrupt factor detection flag [n]
System area
Alert output flag (Process alarm upper limit)
Alert output flag (Process alarm lower limit)
Alert output flag (Rate alarm upper limit)
Alert output flag (Rate alarm lower limit)
System area
Disconnection detection flag
Conversion completed flag
System area
Cold junction compensation setting status
System area
Level data 0
Level data 1
Level data 2
Level data 3
Level data 4
Level data 5
Level data 6
Level data 7
Level data 8
Level data 9
System area
*1
Interrupt factor mask [n]
System area
*1
Interrupt factor reset request [n]
System area
Interrupt factor generation setting [n]
System area
*1
Condition target setting [n]
System area
Condition target channel setting [n]
System area
Mode switching setting
Cold junction compensation with/without setting
System area
Disconnection detection automatic clear enable/disable
setting
System area
Default value
0
0
0
0
0
0000H
0000H
0000H
0000H
0000H
0000H
*2
0
0
0
0
0
0
0
0
0
0
0
0
0
*1
0
0
*1
0
0
*2
0
1
Data type
Auto refresh
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Monitor
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Control
Setting
Setting
Setting
Setting
Setting
Setting

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R60td8-gR60rd8-g

Table of Contents