TeamPoS 2000
7.5

Lead Acid Battery Replacement

Caution: To prevent electric shock, confirm that the AC cable is removed from
1. Remove the front cover (see section 5.1.1).
2.
Remove the metal cover plate on the front-right side of unit over the panel with LEDs
and Power Switch. It is secured with a screw in the center of the top cover.
3.
Disconnect the cable connector of the lead acid battery from the cable connector with
a BATT label. On the new replacement battery, use indelible ink to write the date the
battery was replaced using this format: "Battery Replaced DD/MM/YY".
4.
Mount the new battery in the unit. Connect the battery cable with the connector labeled
BATT.
5.
Attach the cover plate.
6.
Attach the front cover.
90000291
the AC outlet anytime the covers are removed. Be sure to observe all
ESD precautions and power off procedures. Dispose of the battery
in accordance with local regulations for lead acid battery disposal.