Cable routing for PROFIBUS or PROFINET connection to the Control Unit
1.
2.
3.
4.
5.
6.
7.
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
Feed the cable for the Control Unit into the cabinet from the bottom left.
Remove approx. 3 cm of the cable insulation at the level of the shield plate in the lower part of
the cabinet and attach the cable there.
To secure the cable in accordance with EMC requirements, snap the clip onto the shield plate.
Use cable ties to secure the cable at suitable points.
Route the cable further in the cabinet to the upper side of the Control Unit. When doing so, route
the cable in a similar manner to the standard cables that have already been installed in the cabi-
net.
Use cable ties to secure the cable at suitable points.
Connect the cable to the Control Unit.
(→See SINAMICS S120 Manual GH1 Control Units)
Electrical installation
4.5 Connections
103