X520 encoder connection 1 for HTL/TTL/SSI encoder with open-circuit monitoring
Table 9- 28
Connector
Connector type: 15-pin Sub-D socket
Measuring current via temperature sensor connection: 2 mA
Accuracy of the temperature measurement:
1)
- KTY: ±7 °C (including evaluation)
- PT1000: ±5 °C (PT1000 tolerance class B according to EN 60751 including evaluation)
- PTC: ±5 °C (including evaluation)
NOTICE
Damage to the motor in the event of incorrectly connected KTY temperature sensor
If a KTY temperature sensor is connected with incorrect polarity, it is not possible to detect
when the motor overheats. Overheating can cause damage to the motor.
• Connect a KTY temperature sensor with the correct polarity.
NOTICE
Damage to the encoder due to incorrect supply voltage
The encoder power supply can be parameterized to 5 V or 24 V. The encoder may be
damaged if you enter the wrong parameter.
• Select the appropriate supply voltage.
Cabinet Modules liquid cooled
Equipment Manual, 04/2020, A5E37067587A
Encoder connection X520
Pin
Signal name
1
+Temp
1)
2
Clock
3
Clock*
4
P encoder 5 V / 24 V
5
P encoder 5 V / 24 V
6
P sense
7
M encoder (M)
8
-Temp
1)
9
M sense
10
R
11
R*
12
B*
13
B
14
A*/data*
15
A/data
9.14 K50, Sensor Module Cabinet-Mounted SMC30
Technical data
Temperature sensor connection KTY84-1C130
/ PT1000 / PTC
Bimetallic switch with NC contact
SSI clock
Inverted SSI clock
Encoder power supply
Encoder power supply
Sense input for encoder power supply
Ground for encoder power supply
Temperature sensor connection KTY84-1C130
/ PT1000 / PTC
Bimetallic switch with NC contact
Ground for sense input
Reference signal R
Inverted reference signal R
Inverted incremental signal B
Incremental signal B
Inverted incremental signal A/inverted SSI data
Incremental signal A/SSI data