5. Manual Regeneration Completed (Successful)
When manual regeneration is completed,
"Regeneration Has Completed." message will be
displayed and the regeneration symbol disappears.
6. Manual Regeneration Failed (Unsuccessful)
If the message "Regeneration Has Failed." appears on
the monitor panel, start the regeneration process over
again.
Failure to regenerate manually may be caused by a
problem not in the above list, such as malfunction of
a sensor that affects regeneration at a low ambient
temperature.
f
NOTE: Aftertreatment device regeneration cannot be
started when the hydraulic oil temperature is too high. Run
the engine at low idle to lower the oil temperature, and
restart the procedure.
f
NOTE: If aftertreatment device regeneration switch (3)
is pressed when the ambient temperature is low, it may
take long to start the aftertreatment device regeneration
process.
Before pressing aftertreatment device regeneration switch
(3), increase the coolant temperature to about 70°C (158°F)
until the coolant temperature gauge needle starts moving.
Refer to page 3-12 for warm-up in cold weather.
IMPORTANT: If regeneration must be interrupted, press
manual regeneration switch (3) again.
The message "Regeneration Has Failed." will be
displayed on the monitor, and the machine becomes
operable.
In this case, manual regeneration must be done later.
Perform the manual regeneration again as soon as
possible.
OPERATING THE MACHINE
5-15
MNEK-01-284EN
MNEK-01-285EN