Check Def/Adblue® Level; Refill Def/Adblue - Hitachi ZW 310-6 Operator's Manual

Wheel loader
Hide thumbs Also See for ZW 310-6:
Table of Contents

Advertisement

Check DEF/AdBlue® Level
---daily
Park the machine on a level surface. Lower the bucket
to the ground. Check the DEF/AdBlue® level with DEF/
AdBlue® gauge (1).
Add DEF/AdBlue® if necessary.
Refill DEF/AdBlue®
d
CAUTION:
 Refill DEF/AdBlue® which meets Japanese
Industrial Standards (JIS K2247), International
Organization for Standardization (ISO 22241) or
Deutsche Industrie Normen (DIN 70070) in DEF/
AdBlue® tank (2). If low density DEF/AdBlue®
is refilled, alarm will be generated, restricting
machine operation. Do not dilute DEF/AdBlue®
with water.
 Use rubber gloves for protection during
operation. Wash DEF/AdBlue® with clean water
when it contacts on the skin.
1. Park the machine following the same procedures as
described on page 7-7 for preparation of inspection/
maintenance work.
2. DEF/AdBlue® tank (2) is located in the cover at left
rear of the machine. Open and secure the cover by
turning stopper plate (3) downward.
3. Clean dust and mud around the filler port of DEF/
AdBlue® tank with clean cloth.
4. Remove cap (4) from DEF/AdBlue® tank (2) and refill
DEF/AdBlue®.
Be sure to stop refilling before "MAX" line (5).
IMPORTANT:
 Take care not to allow dust and/or water to enter
the DEF/AdBlue® tank when refilling.
 If DEF/AdBlue® is filled above the "MAX" line, the
system may be damaged during operation or
tank (2) may be broken when frozen.
MAINTENANCE
4
7-106
MNEK-01-103EN
3
2
5
90Z7B-7-118-2
1