Check Gas Pressure In Accumulator; Check Brake Disks (Service And Parking) - Hitachi ZW 310-6 Operator's Manual

Wheel loader
Hide thumbs Also See for ZW 310-6:
Table of Contents

Advertisement

Check Gas Pressure in Accumulator

--- every 2000 hours
Check the gas pressure at a regular interval. If the
machine is operated with the gas pressure lower than
specified value, normal brake performance and/or loading
performance may not be to specifications achieved,
possibly creating very hazardous situations. Ask your
nearest authorized dealer for checking.
f
NOTE: Check the accumulator for the ride control
equipped machine in the same manner.

Check Brake Disks (Service and Parking)

--- every 2000 hours
Service brake (1) is a closed wet type brake.
Parking brake (2) is also a closed wet type brake.
Parking brake (2) is mounted in the transmission.
Consult your nearest authorized dealer for checking.