MS2N Synchronous Servomotors
CAUTION
For safe switching of the holding brake, a rated voltage of 24 V DC ±10% is re-
quired at the motor.
Ensure correct dimensioning of the supply wires (wire length and cross-section)
for the holding brake.
The control voltage can be reduced using the energy saving function after safely
releasing the brake, see
page
29.
Protective circuit
The holding brakes are intended for direct connection to the IndraDrive control-
ler. A protective circuit to switch inductive loads of holding brakes is integrated
in IndraDrive controllers. Please observe when operating of third-party convert-
ers that MS2N motors do not have an integrated protective circuit.

Technical data holding brakes

Data sheet - Holding brake
Type
MS2N03-B____-____1-_____-
__
MS2N03-D____-____1-_____-
__
MS2N04-B____-____1-_____-
__
MS2N04-C____-____1-_____-
__
MS2N04-D____-____1-_____-
__
MS2N05-B____-____1-_____-
__
MS2N05-C____-____1-_____-
__
MS2N05-D____-____1-_____-
__
MS2N06-B____-____1-_____-
__
1) Tolerance ± 10%
Malfunction in case of exceeded tolerance of
the rated voltage (switching voltage)
chapter "Energy saving function for holding brakes" on
Holding
Dynamic
Rated
torque
braking
voltage
torque
M
M
U
4
1
N
Nm
Nm
V
1.80
1.3
24
1.80
1.3
24
5.00
4.5
24
5.00
4.5
24
5.00
4.5
24
10.00
4.5
24
10.00
4.5
24
10.00
4.5
24
10.00
4.5
24
Rated
Maxi-
Maxi-
current
mum
mum dis-
1)
connec-
connec-
tion time
tion time
I
t
t
N
1
2
A
ms
ms
0.46
8
35
0.46
8
35
0.63
30
45
0.63
30
45
0.63
30
45
0.73
30
80
0.73
30
80
0.73
30
80
0.73
30
80
R911347581_Edition 04 Bosch Rexroth AG
27/101
About this product
Moment of
Maxi-
inertia of the
mum
holding
switched
brake
energy
J
W
br
max
J
kg*m
2
0.0000074 300
0.0000074 300
0.0000451 400
0.0000451 400
0.0000451 400
0.0001070 400
0.0001070 400
0.0001070 400
0.0001070 400