66/101
Assembly
1)
only applicable to MS2N13 motors
Fig. 6-4: MS2N terminal boxes "C"
Terminal boxes "C", power (double cable connection)
Clamp / data
MS2N
1) 2)
U
Bolts M8, M
V
Rated cross section 50 mm
W
Rated current 150 A
1
2
Tension spring connection 0.5 ... 2.5 mm
ferrule
3
4
Screwed connection M8, M
Shld
1)
Terminal 1, 2 are not assigned for motors without holding brake.
2)
Terminal 3, 4 are not assigned for encoder Cx, Dx. The motor temperature is transmitted via the encoder inter-
face.
3)
Assign not used connection wires within the terminal box.
Tab. 6-23: MS2N Pin assignment terminal boxes "C"
Bosch Rexroth AG R911347581_Edition 04
6 ... 12 Nm
A
2
3.8 Nm
A
MS2N Synchronous Servomotors
ctrlX /
IndraDrive
A1
A2
A3
BD(+)
BD(-)
2
with wire end
TP1(+)
TP2(-)
PE
Shld
Cables RL2,
RLB2, REL, INK
3)
1
2
3
7
8
5
6
GNYE