46/101
Operating conditions and handling
If provided by the manufacturer, all lifting eye bolts must be used and tight-
ened before use.
Avoid increased transport vibrations.
Remove any existing transport locks prior to commissioning and keep them.

5.5 Bearing

Store the motors in their original packaging in a dry, dust-free, vibration-free and
light-protected place without direct solar radiation. Please observe classes
1K21, 1B1, 1C1, 1S10, 1M11 specified for storage acc. to DIN EN 60721-3-1.
Please observe the following classification limitations:
Bearing
Ambient temperature
Relative air humidity
Absolute air humidity
Direct solar radiation
Shock load
Tab. 5-7: Classification limitation (DIN EN IEC 60721-3-1)
NOTICE
Protect the products from dampness and corrosion.
Store them only in rainproof and dry rooms.
Before storage, discharge the liquid coolant from liquid-cooled mo-
tors to avoid frost damage.
Additional measures have to taken upon commissioning to ensure smooth
functioning - irrespective of the storage time which may be longer than the
warranty period of our products. Warranty extension is not a consequence.
Motors
Storage time/months
> 1
> 12
Bosch Rexroth AG R911347581_Edition 04
Damage due to moisture and humidity!
Measures for commissioning
> 60
Visual inspection of all parts to be damage-free
Resurface the holding brake
Check the electric contacts to verify that they are free from corrosion
Let the motor run in without load for one hour at 800 ... 1000 rpm.
MS2N Synchronous Servomotors
-25 ... +55 °C
5 ... 75 %
1 ... 29 g/m³
Not permitted
Refer to section shock load during transport und
storage