46/101
Operating conditions and handling
If provided by the manufacturer, all lifting eye bolts must be used and tight-
●
ened before use.
Avoid increased transport vibrations.
●
Remove any existing transport locks prior to commissioning and keep them.
●
5.5 Bearing
Store the motors in their original packaging in a dry, dust-free, vibration-free and
light-protected place without direct solar radiation. Please observe classes
1K21, 1B1, 1C1, 1S10, 1M11 specified for storage acc. to DIN EN 60721-3-1.
Please observe the following classification limitations:
Bearing
Ambient temperature
Relative air humidity
Absolute air humidity
Direct solar radiation
Shock load
Tab. 5-7: Classification limitation (DIN EN IEC 60721-3-1)
NOTICE
Protect the products from dampness and corrosion.
●
Store them only in rainproof and dry rooms.
●
Before storage, discharge the liquid coolant from liquid-cooled mo-
tors to avoid frost damage.
Additional measures have to taken upon commissioning to ensure smooth
functioning - irrespective of the storage time which may be longer than the
warranty period of our products. Warranty extension is not a consequence.
Motors
Storage time/months
> 1
> 12
●
●
●
●
●
●
Bosch Rexroth AG R911347581_Edition 04
Damage due to moisture and humidity!
Measures for commissioning
> 60
●
Visual inspection of all parts to be damage-free
●
Resurface the holding brake
●
Check the electric contacts to verify that they are free from corrosion
●
Let the motor run in without load for one hour at 800 ... 1000 rpm.
MS2N Synchronous Servomotors
-25 ... +55 °C
5 ... 75 %
1 ... 29 g/m³
Not permitted
Refer to section shock load during transport und
storage