Chapter 2 Preparations
(1)
Standard Riser Card
Product
Product
Riser Card name
number
name
Slot number
CPU connected
PCI standard
PCIslot performance *1
Bandwidth/lane *1
PCI board type*2
Slot size
Available size
RAID Controller(0MB, RAID 0/1)
N8103-189
[PCI Express 3.0(x8)]
RAID Controller(2GB, RAID 0/1/5/6)
N8103-190
[PCI Express 3.0(x8)]
RAID Controller(0MB, RAID 0/1)
N8103-195
[PCI Express 3.0(x8)]
RAID Controller(2GB, RAID 0/1/5/6)
N8103-201
[PCI Express 3.0(x8)]
RAID Controller(2GB, RAID 0/1/5/6)
N8103-196
[PCI Express 3.0(x8)]
SASController(2ch)
N8103-197
[PCI Express 3.0(x8)]
1000BASE-T LOMCard(2ch)
N8104-193
[Connect to Chipset]
10GBASE-SFP LOMCard(2ch)
N8104-194
[Connect to Chipset]
10GBASE-T LOMCard(2ch)
N8104-195
[Connect to Chipset]
1000BASE-T LOM board(4ch)
N8104-171
[PCI Express 2.0(x4)]
1000BASE-T LOM board(4ch)
N8104-172
[PCI Express 2.0(x4)]
10GBASE-T LOMboard(2ch)
N8104-173
[PCI Express 2.0(x8)]
10GBASE-T LOMCard(2ch)
N8104-175
[PCI Express 2.0(x8)]
10GBASE LOMboard(SFP+/2ch)
N8104-176
[PCI Express 3.0(x8)]
1000BASE-T board(2ch)
N8104-178
[PCI Express 2.0(x1)]
1000BASE-T board(4ch)
N8104-179
[PCI Express 2.0(x4)]
1000BASE-T board(2ch)
N8104-180
[PCI Express 2.0(x4)]
1000BASE-T board(4ch)
N8104-181
[PCI Express 2.0(x4)]
10GBASE-T board(2ch)
N8104-182
[PCI Express 2.0(x8)]
10GBASE-T board(2ch)
N8104-183
[PCI Express 3.0(x8)]
10GBASE-T board(2ch)
N8104-184
[PCI Express 3.0(x8)]
10GBASE basic board(SFP+/2ch)
N8104-185
[PCI Express 2.0(x8)]
10GBASE basic board(SFP+/2ch)
N8104-186
[PCI Express 3.0(x8)]
88
st
RAID
LOM
1
Riser Card*3
SLOT1
SLOT2
SLOT3
-
-
CPU1
PCIe3.0
x8
x8
x16
x8
x8
x8
8Gb/s
-
-
x16
x8
x8
x8
Dedi-
Dedi-
FH
FH
FH
FH
cated
cated
312
312
168
168
to
to
mm
mm
mm
mm
RAID
LOM
○
-
-
-
-
-
○
-
-
-
-
-
1
-
-
2
(1)
(3)
(2)
1
2
(1)
(3)
-
-
(2)
1
-
-
2
(1)
(3)
(2)
1
2
(1)
(3)
-
-
(2)
-
○
-
-
-
-
-
○
-
-
-
-
-
○
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1
2
(1)
(3)
-
-
(2)
1
2
(1)
(3)
-
-
(2)
1
2
(1)
(3)
-
-
(2)
1
-
-
2
(1)
(3)
(2)
1
-
-
2
(1)
(3)
(2)
1
2
(1)
(3)
-
-
(2)
1
2
(1)
(3)
-
-
(2)
1
2
(1)
(3)
-
-
(2)
1
-
-
2
(1)
(3)
(2)
Express5800/R120h-2E User's Guide
1. Installing Internal Optional Devices
nd
2
Riser Card*3
SLOT4
SLOT5
SLOT6
CPU2
x8
x8
x16
x8
x8
x8
x8
x16
x8
x8
FH
FH
FH
FH
ALOM
168
312
312
168
Only
mm
mm
mm
mm
-
-
-
-
-
Maximum of up to 1 battery per system
-
-
-
-
-
device
For N8116-74 Riser Card, install in order
-
4
5
5
6
of (x).
For N8116-74 Riser Card, install in order
4
5
5
6
-
of (x).
For External drive.
Maximum of up to 1 battery per system
-
4
5
5
6
device
For N8116-74 Riser Card, install in order
of (x)
For External drive.
4
5
5
6
For N8116-74 Riser Card, install in order
-
of (x).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
○
-
-
-
-
○
-
-
-
-
○
-
-
-
-
○
-
-
-
-
○
-
-
-
-
For N8116-74 Riser Card, install in order
4
5
5
6
-
of (x).
Cable with boots are unsupported.
Up to 3 pcs of N8104-179/181 can be
4
5
5
6
installed.
-
For N8116-74 Riser Card, install in order
of (x).
Cable with boots are unsupported.
4
5
5
6
For N8116-74 Riser Card, install in order
-
of (x).
Cable with boots are unsupported.
Up to 3 pcs of N8104-179/181 can be
-
4
5
5
6
installed.
For N8116-74 Riser Card, install in order
of (x).
For N8116-74 Riser Card, install in order
-
4
5
5
6
of (x).
Maximum of up to 1 card per system.
4
5
5
6
For N8116-74 Riser Card, install in order
-
of (x).
For N8116-74 Riser Card, install in order
4
5
5
6
-
of (x).
For N8116-74 Riser Card, install in order
4
5
5
6
-
of (x).
For N8116-74 Riser Card, install in order
-
4
5
5
6
of (x).
(1/2)
Remarks