AIR INDUCTION SYSTEM
CHECKING THE AIR INDUCTION SYSTEM
1. Check:
D hoses
1
Loose connection Connect properly.
Cracks/damage Replace.
D pipes
2
Cracks/damage Replace.
2. Check:
D air filter element
Damage Replace.
3. Clean:
D air filter element
Apply compressed air to the inner surface of
the air filter element.
4. Check:
D fiber reed
D fiber reed stopper
D reed valve seat
Cracks/damage Replace the reed valve.
6-19
CARB
1