Acceleration/Deceleration By Plsv Instruction - Mitsubishi Electric FX3S Series User Manual

Hide thumbs Also See for FX3S Series:
Table of Contents

Advertisement

FX
/FX
/FX
3S
3G
3GC
Built-in Positioning Functions
4.3.9

Acceleration/Deceleration by PLSV Instruction

Using an FX
(M8338) is turned on, the variable speed pulse output (PLSV) instruction will be activated to accelerate/
decelerate the operation.
This means that if the command value of the output pulse frequency is changed, the operation will be
accelerated or decelerated to the changed output pulse frequency depending on the specified acceleration/
deceleration time.
Caution:
• To enable acceleration/deceleration, turn on M8338 first, and then activate the variable speed pulse output
(PLSV) instruction.
• If acceleration/deceleration is enabled, the variable speed pulse output (PLSV) instructions of all the pulse
output destination devices will accelerate/decelerate with the same time. This means that acceleration/
deceleration cannot be specified separately for each pulse output destination device.
B - 64
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
PLC Ver. 2.20 or later and FX
3UC
Output
pulse
frequency
Bias speed
Initial value: 0 Hz
Acceleration
time
Initial value: 100 ms
search engine
/FX
/FX
/FX
3S
3G
3GC
3U
For operation of PLSV instruction, refer to Chapter 10.
Maximum speed
Initial value: 100,000 Hz
Deceleration time
Initial value: 100 ms
4 Before Programming
4.3 Various Special Relays for Operation Commands
PLC, if acceleration/deceleration operation
Bias speed