Built-in Positioning Functions
1.5
Assignment of Input/Output Numbers
1.5.1
Assignment of Input Numbers
Assign the input numbers of the FX
Application
Stop command
Zero return
command
Near-point
signal
(DOG)
Zero-phase
signal
ABS read
JOG command
B - 10
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
Input number
Connect a line to any input.
All input
If the line-connected input is turned on, turn off the positioning instruction signal
points
must be turned off.
Connect a line to any input.
All input
If the line-connected input is turned on, the DSZR or ZRN instruction must be
points
turned on.
Connect a line to the input of the near-point signal (DOG) specified by DSZR or
ZRN instruction.
All input
points
Point:
• To use the ZRN instruction:
X000 to
Connect a line to the input specified for the zero-phase signal (this input is
*1
specified by DSZR instruction).
X007
Connect a line if it is necessary to use the absolute position detection system.
All input
Connect a line to the input specified by the ABS instruction.
points
Use 3 consecutive input points for this function.
Connect a line to any input.
All input
If the line-connected input is turned on, the DRVI instruction for the jogging motion
points
must be turned on.
search engine
/FX
/FX
/FX
/FX
3S
3G
3GC
3U
3UC
For details on the near-point signal of the DSZR instruction, refer to
For details on the near-point signal of the ZRN instruction, refer to
*1
If X000 to X007
of the main unit are set for the near-point signal (DOG), the
PLC interruption function will be used for processing of the near-point signal
(DOG).
1.5 Assignment of Input/Output Numbers
PLC as follows:
Remarks
1 Outline
Section 6.2.
Section 6.3.