Mitsubishi Electric FX3S Series User Manual page 151

Hide thumbs Also See for FX3S Series:
Table of Contents

Advertisement

FX
/FX
/FX
3S
3G
3GC
Built-in Positioning Functions
4) If the limit switch in the zero return direction turns ON (if the start position is at forward rotation limit 1 or
reverse rotation limit 1):
a) When the zero return instruction is executed, zero return will be started.
b) Transfer operation will be started in the opposite direction of the zero return direction at the zero return
c) If the front end of the DOG is detected, the speed will decelerate and the operation will stop. (The
d) Transfer operation will be restarted in the zero return direction at the zero return speed (and the
e) If the front end of the DOG is detected, the speed will be reduced to the creep speed.
f) After detecting the rear end of the DOG, if the first zero-phase signal is detected, the operation will be
Downloaded from
ManualsNet.com
/FX
/FX
PLC User's Manual - Positioning Control Edition
3U
3UC
speed.
workpiece will detect the DOG and then come out of the DOG area.)
workpiece will enter the DOG area again).
stopped.
search engine
6 Mechanical Zero Return - DSZR/ZRN Instruction
6.2 DOG Search Zero Return (DSZR Instruction)
A
B
Apx.
B - 107

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fx3g seriesFx3gc seriesFx3u seriesFx3uc series

Table of Contents