3-3 Connections

3-3-1 Cable connection

* MX-NL series don't have V2, V3.
KD6R309MX
V1
V2
D1◎
D2
KD6R617MX
V1
V2/V3
D1◎
D2
D3
D4
KD6R926MX
V1
V2/V3
D1◎
D2
D3
D4
D5
D6
TM-XG537C
【 Remarks 】 (for connection)
◎ : Master port
When using multiple grabber boards, make sure to input
External synchronization signal and Communication control
+5V
only through the connecter defined as Master port on the left.
+24V
CH 0
【 Remarks 】
<Grabber board 1>
CH 1
This product is synchronized based on a line data.
However, it is operated by individually independent
CLK for each 309mm-size block. In other word, each
+5V
309mm-size block are not synchronized based on CLK.
+24V
CH 0
The length of the Camera Link® cable varies depending on
<Grabber board 1>
CH 1
the environment and connection status.
CH 0
<Grabber board 2>
Please select cables that can communicate and acquire
CH 1
images normally.
If an error occurs in communication and image acquisition,
+5V
please lower the frequency of Camera Link® (minimum).
+24V
And please adjust the length of the recommended cable
CH 0
(P.48) and re-acquire communications and images.
<Grabber board 1>
CH 1
If communication and acquisition the images is possible, it is
CH 0
<Grabber board 2>
presumed that the cause is Camera Link® or the length of
CH 1
Camera Link® , not a trouble of this product.
CH 0
In such a case, Mitsubishi Electric assumes no
<Grabber board 3>
CH 1
responsibility.
Camera Link® is a registered trademark of AIA(Automated Imaging Association)
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
47