Mitsubishi Electric KD Series User Manual page 57

Contact image sensor for web surface inspection
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

4-2 Communication (User setting)
4-2-4 Memory (user setting)
Directions of Communication
Microcomputer
Setting memory
Every setting area have
4 parameter tables
Following ①~③ in the diagram show the route of
operation data transference.
① UART ⇔ Operation registers in ASIC/FPGA.
② UART ⇔ Setting memory (FLASH memory)
③ Setting memory ⇔ Operation registers in ASIC/FPGA.
TM-XG537C
【 User setting memory area 】
setting2 and User setting3 , for storing setting data which
Initial data memory
Operation registers
customer makes under unique conditions.
1) Adjust Registers on ASIC/FPGA by UART under target
2) Store ASIC/FPGA register data to User setting memory
【 Remarks 】
1) It is available to read out the following data from the
2) Refer Chapter 5 of this document and the function
3) The initial data which are set at factory adjustment are
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
This product has 3 memory area, User setting1,User
The procedure to make new setting data is as following.
condition of the Inspection.
area .(Using memory transfer command from UART)
storing memory .
- γ correction data
- Control register value
- White correction data
- Dark correction data
specification document how to store user setting data to
the storing memory and detail procedure of it .
stored in this memory area . Customer can not over-
write date in this area .
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents