Mitsubishi Electric KD Series User Manual page 89

Contact image sensor for web surface inspection
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

No.
Command
function
Syncronous Sygnal
4
SS
mode setting
Light Source
5
LC
Control
TM-XG537C
Appendix D: Command list ③
Code
SS 00 (1C) (DF) CR
Internal Sync. Mode & Pulse width setting
SS 01 CR
External sync. <Mode
SS 80 CR
Sync. Mode setting Read-Out
LC 00 CR
Light Source Turn-OFF
LC 01 CR
1 pulse setting : Light-Source A turn ON
LC 02 CR
1 pulse setting : Light-Source B turn ON
LC 03 CR
1 pulse setting : Light-Source A/B turn ON
LC 04 CR
Light Source Turn-OFF
LC 05 CR
2 pulse setting : Light-Source A turn ON
LC 06 CR
2 pulse setting : Light-Source B turn ON
LC 07 CR
2 pulse setting : Light-Source A/B turn ON
LC 08 CR
Light Source Turn-OFF
LC 09 CR
4 pulse setting : Light-Source A turn ON
LC 0A CR
4 pulse setting : Light-Source B turn ON
LC 0B CR
4 pulse setting : Light-Source A/B turn ON
LC 0C CR
Light Source Turn-OFF
LC 0D CR
8 pulse setting : Light-Source A turn ON
LC 0E CR
8 pulse setting : Light-Source B turn ON
LC 0F CR
8 pulse setting : Light-Source A/B turn ON
LC 20 (02) (58) CR
Light Source A Pulse width setting
LC 40 (02) (58) CR
Light Source B Pulse width setting
LC 60 (02) (D0) CR Pulse-width valid perid setting
LC A0 CR
Read-Out Setting Value of Light source A
LC C0 CR
Read-Out Setting Value of Light source B
LC E0 CR
Read-Out Setting Value of Pulse-width valid perid
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Detail
Set 88usec/line at Camera Link®
Output Frequency 84MHz
* () shows setting data.
set pulse width 37.0usec
*() shows setting-data
set pulse width 37.0usec
*() shows setting-data
set Valid period of the pulse width
45.0usec
*() shows setting-data