Mitsubishi Electric KD Series User Manual page 51

Contact image sensor for web surface inspection
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

3-3 Connections
3-3-5 MX-NL series LED Control signal output
* This Connector is available only for MX-NL series CIS
without illumination .
L1
Signal Timing chart
Delay period from internal line start signal 3.6μsec(fixed)
External sync.
signal CC1
Line period
(Input from
connector D1)
( Internal signal)
LED turn off
Internal Delay
LED Control pulse
OUT PULSE1
OUT PULSE2
TM-XG537C
LED turn on
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
Be sure to check connection interface (connector joint, wire diameter)
【 LED Control signal Output 】
Cable is not in product package. Prepare it by yourself.
1) It is available to control External illumination by using
illumination control signals (OUT_PULSE1, OUT_PULSE2)
output from Connector L1 ,4
th
2) CIS is equipped with
DEU-9S-F0R ( by JAE) as connectors,
030-50640 ( by JAE) as contact socket.
3) Connector for Power Cable (strongly recommend using)
DEU-9P-F0R ( by JAE ) as contact socket housing,
030-50641 ( by JAE) as contact pin.
* Connector and Contact socket are different between MX-
NL series without illumination and MX series with
illumination.
4) Pin assignment table is following .
(KD-MX-NL series)
No
Name
I/O
1
NC
2
NC
3
NC
4
OUT PULSE1
5
NC
6
NC
7
NC
8
OUT PULSE2
9
GND
5) When adjusting the pulse width of the lighting trigger
signal to control commands. Refer to the functional
specification for more information.
before using the product.
and 8th-pin .
note
-
-
-
O
3.3V LVTTL
-
-
-
O
3.3V LVTTL
I
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents