5-2 Setting ④ Select resolution
5-2-4 Resolution setting for Main scan direction
【 Input 】
【 Output 】
Command Parameter CR
Result Parameter
RC
**
CR
**
[initial Value]
600dpi
[Settings] Resolution 75dpi , 150dpi ,300dpi ,600dpi
1) Pixel data structure at 600dpi mode
600dpi
2) Pixel data structure at 3000dpi mode
300dpi ( Average of 2 neighbor pixels )
3) Pixel data structure at 150dpi mode
150dpi Average of 4 neighbor pixels )
4) Pixel data structure at 75dpi mode
75dpi ( Average of 8 neighbor pixels )
Example
Set resolution to 600dpi mode
RC 00 <CR>
00 00
TM-XG537C
CR
**
CR
<CR>
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【 Resolution setting for Main scan direction 】
[Function]
to define a resolution of output image data .
Pixel pitch of sensor IC is 600dpi and Optical resolution is
also same as Pixel pitch (600dpi).
Variation of output resolution is realized by digital
processing on data output circuit . Each resolution data
comes from calculation of neighbor 2,4,8 pixel averaging.
【 Remarks 】
1) Pixel pitch of sensor IC is 600dpi and Optical resolution
is also same as Pixel pitch (600dpi). And internal data
processing of CIS is handled as 600dpi data .
2) Scan rate is not faster than specified line rate on spec.
sheet even so resolution of data output is lower .
3) If it is necessary for scanning image to have square
pixel , should be change the transfer speed of the
object as following .
300dpi : 2 times faster than 600dpi mode
150dpi : 4 times faster than 600dpi mode
75dpi : 8 times faster than 600dpi mode