9-10 Upgrading Your Server
13.
Remove the paper protecting the cool sheet from the rear face of the heat sink. Take care
not to touch the cool sheet with your hand.
IMPORTANT:
scratches.
14.
Place the heat sink on the CPU and secure it with four screws.
15.
When installing the CPU heat sink, loosely fasten the four screws by the cross-coupling
method, and then tighten them securely after making sure that the heat sink is properly
seated in the CPU socket.
1
16.
Replace the cover and install the CPU blade in the Blade Enclosure.
17.
Power on the CPU blade. In the BIOS Setup utility, set [Advanced] – [Reset
Configuration Data] to [Yes].
This is required to update the hardware configuration information. See Chapter 4 for
details.
18.
Open "Device Manager. " If the "Computer" driver is set to "ACPI uni-processor PC" or
"ACPI single-processor PC," change it to "ACPI multi-processor PC." Reboot the system
and run NEC EXPRESSBUILDER in Windows to update the system.
Perform the above procedure if
– The system is running under the Windows operating system
– The system has a 1-CPU configuration
This procedure is not required if the "Computer" driver is set to "ACPI multi-processor
PC."
Make sure to protect the cool sheet from dirt or
2