NEC BladeServer Express5800 Series User Manual page 78

Hide thumbs Also See for BladeServer Express5800 Series:
Table of Contents

Advertisement

See the table below for the options and their descriptions:
Option
FRB-2 Policy
Boot Monitoring
Thermal Sensor
BMC IRQ
Post Error Pause
AC-LINK
NOTE:
information on the AC-LINK feature.
The table below shows the system status when AC power to the server is turned off and then
restored:
System status before AC power off
Operating
Shutdown (DC power off)
Forced shutdown*
* Press the POWER switch for four seconds or longer. This forcibly turns off the power.
Parameter
Disable FRB2 Timer
[Disable BSP]
Do Not Disable BSP
Retry 3 Times
[Disabled]
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Disabled
[Enabled]
Disabled
[IRQ 11]
Disabled
[Enabled]
Stay Off
[Last State]
Power On
Refer to the User's Guide of the Blade Enclosure for more
Configuring Your Server 4-21
Description
Set the policy to be applied to FRB
level 2 timer.
Specify whether the boot
monitoring feature is enabled or
disabled and the timer value.
To use this feature, install NEC
ESMPRO Agent. Do not use this
feature if the system is booted
from the operating system without
NEC ESMPRO Agent installed.
Set this item to "Disabled" if
ARCServe uses the Disaster
Recovery Option.
Specify whether the temperature
sensor monitoring function is
enabled or disabled.
Specify the IRQ of the BMC.
Specify whether POST is halted if
an error occurs.
Specify the AC-LINK feature.
Select the state when the power of
the CPU blade is restored. See
the table below.
Setting of AC-LINK
Stay Off
Last State
Off
On
Off
Off
Off
Off
Your Setting
[
]: Factory-set
Power On
On
On
On

Advertisement

Table of Contents
loading

This manual is also suitable for:

N8400-071afN8400-072afN8400-073afN8400-074af