5.
Click [Settings] in the [Performance] box.
The [Performance Options] window appears.
6.
Click the [Advanced] tab in the [Performance Options] window.
7.
Click [Change] in the [Virtual memory] box.
8.
Change the value set for [Initial Size] in the [Paging file size for selected drive] box to the
[Recommended] value or more, and then click [Set].
IMPORTANT:
Be sure to set the paging file size to more than the [Recommended]
value in the OS partition. If a value smaller than the [Recommended]
value is set for [Initial Size] of the paging file, accurate debug
information (memory dump) may not be collected.
For more information on the "Recommended" value, see "About the
System Partition Size" described earlier.
If the memory is expanded, reset the paging file size according to the
memory size.
9.
Click [OK].
A message is displayed asking you to restart the system depending on the settings changed.
Restart the system according to the message.