NetCol5000-A050 In-row Air Cooled Smart Cooling
Product
User Manual (1350 mm Depth)
No.
5
6
7
8
9
10
11
Issue 04 (2022-12-15)
Name
Description
Wet film
● Uses wet film for humidification with low water
humidifier
● Has a simple structure and is easy to remove, clean,
● Quickly starts and generates huge humidification
● Consumes low power, saving more than 95% energy
● Provides a longer service life and maintenance
Compressor
● The smart cooling product uses a DC variable-
● The high-precision drive automatically adapts to the
● The drive conducts precision self-check. Compressor
Filter dryer
The filter dryer absorbs water from the refrigerant
pipes and filters out the foreign matter, which reduces
component damage rates and improves operating
efficiency and reliability.
Sight glass
Allows you to observe the refrigerant flow and gas
content for easy maintenance and optimization.
Oil separator
The oil separator separates the lubricant brought out
due to discharge of the compressor and brings back the
separated lubricant to the compressor.
Electronic
● The throttling device changes the flow area of the
expansion
valve (EEV)
● The main control module contains an EEV energy
Drive
● The variable-frequency compressor drive, outdoor
● The compressor drive is controlled over RS485. You
Copyright © Huawei Digital Power Technologies Co., Ltd.
quality requirements and high environment
adaptability.
and maintain.
capacity.
compared with a traditional electrode humidifier.
interval than a traditional electrode humidifier.
frequency compressor that features compact size,
light weight, a long service life, low noise, easy
installation, high reliability, stability, and energy
efficiency.
system pressure fluctuations.
and drive faults are separated.
valve port by controlling the operation of the micro
stepper motor, thereby accurately adjusting the
refrigerant flow of the cooling system.
storage unit to prevent slugging due to refrigerant
migration after an unexpected power-off.
fan, and 24 V power module are integrated into one
device to save space in the smart cooling product
and improve efficiency.
can view the drive running status and parameters
on the LCD in real time to facilitate fault locating.
2 Product Description