Bleeding the Fuel System
You must bleed the fuel system before starting the
engine if any of the following situations have occurred:
•
Initial startup of a new machine
•
The engine has ceased running due to a lack of
fuel.
•
Maintenance has been performed upon
fuel-system components (e.g., filter replaced).
1.
Turn the key to the RUN position.
2.
Let the fuel pump run for 2 minutes prior to
starting the machine.
Draining the Fuel Tank(s)
Service Interval: Every 2 years
Have an Authorized Service Dealer drain and clean
the fuel tank(s).
Electrical System
Maintenance
Electrical System Safety
•
Disconnect the battery before making any repairs;
refer to
Using the Battery-Disconnect Switch (page
36).
•
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.
•
Battery acid is poisonous and can cause burns.
Avoid contact with skin, eyes, and clothing. Protect
your face, eyes, and clothing when working with a
battery.
•
Battery gases can explode. Keep cigarettes,
sparks, and flames away from the battery.
Using the
Battery-Disconnect Switch
1.
Park the machine on a level surface, engage the
parking brake, and lower the loader arms.
2.
Shut off the engine and remove the key.
3.
Open the hood.
4.
Turn the battery-disconnect switch to the O
O
position.
FF
1. De-energize the
machine—rotate the
battery-disconnect switch
to the O
position.
FF
36
Figure 48
2. Energize the
machine—rotate the
battery-disconnect switch
to the O
position.
N
or
N
g365602