Bleeding the Fuel System

You must bleed the fuel system before starting the
engine if any of the following situations have occurred:
Initial startup of a new machine
The engine has ceased running due to a lack of
fuel.
Maintenance has been performed upon
fuel-system components (e.g., filter replaced).
1.
Turn the key to the RUN position.
2.
Let the fuel pump run for 2 minutes prior to
starting the machine.

Draining the Fuel Tank(s)

Service Interval: Every 2 years
Have an Authorized Service Dealer drain and clean
the fuel tank(s).
Electrical System
Maintenance

Electrical System Safety

Disconnect the battery before making any repairs;
refer to
Using the Battery-Disconnect Switch (page
36).
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.
Battery acid is poisonous and can cause burns.
Avoid contact with skin, eyes, and clothing. Protect
your face, eyes, and clothing when working with a
battery.
Battery gases can explode. Keep cigarettes,
sparks, and flames away from the battery.
Using the
Battery-Disconnect Switch
1.
Park the machine on a level surface, engage the
parking brake, and lower the loader arms.
2.
Shut off the engine and remove the key.
3.
Open the hood.
4.
Turn the battery-disconnect switch to the O
O
position.
FF
1. De-energize the
machine—rotate the
battery-disconnect switch
to the O
position.
FF
36
Figure 48
2. Energize the
machine—rotate the
battery-disconnect switch
to the O
position.
N
or
N
g365602