Panasonic VB-44210G User Manual page 324

Digital business system
Table of Contents

Advertisement

Appendix A. EX 1.0 Feature Update
Related Programming
• FF1 (System): SMDR Print
• FF1 (System): Parity Check
• FF1 (System): Odd/Even Parity
• FF1 (System): Baud Rate
• FF1 (System): Stop Bit Length
• FF1 (System): Data Length
• FF1 (System): Serial Port Flow Control (X On/ X Off)
• FF1 (System): SMDR Display Start Timer for CO Calls
• FF1 (System): SMDR Printing Mode 1: Outbound, Inbound, Network
• FF1 (System): SMDR Printing Mode 2: Long Distance and Local Calls
• FF1 (System): SMDR Printing Mode 3: Header Title
• FF3 (Extension) Station Message Detail Recorder (SMDR) Report
Hardware Requirements
• A printer or external call accounting system is required to receive SMDR
Considerations
• Unlike other CPC circuit cards, the CPC-EX supports two serial ports.
• Be sure to select the correct port to output SMDR data. From the
Page A-34
data.
Serial Port 1 is labeled CN4 and is located on the backplane. Serial Port 2
is labeled CN5 and is located on the front of the CPC-EX card. Serial Port
2 requires a special interface cable.
Attendant's phone:
- dial #90 to set Serial Port 1 (the backplane port) to output Bus
Monitor/Maintenance and Serial Port 2 to no output.
- dial #92 to set Serial Port 1 to output SMDR and Serial Port 2
to output Bus Monitor/Maintenance data.
- dial #93 to set Serial Port 1 to output SMDR data and Serial
Port 2 to no output.
DBS Manual - Revised April 2000
Section 700-Operation
DBS-2.3/9.2-700

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents