Saved folder name setting
Window
Click the [Edit] button on the [Folder] tab of the data logging setting screen.
Displayed items
Item
*1*2*3
Simple setting
Add the name
Add the date
Add the time
Add the sequential number
*3*5
Detailed setting
Format
Attached data
setting
Example
*1 The format is fixed as follows. When the selected items are outputted in the following sequence, and when there are multiple items
specified, they are outputted with "_" in between.
Name_date_time_sequential number
*2 Adding name only cannot be allowed. Add the combination of any of the date, time, or sequential number.
*3 When writing the setting after changing the saved folder name setting, updating the setting, or powering OFF  ON, the folder used
before changing the setting is switched and the saved file is stored in a new folder.
*4 For the sequential 8 digit hexadecimal number, the same number as the sequential number of saved file which is stored at file switching
is added. (Page 60 Add the sequential number of subscripts)
*5 Only fixed string cannot be set for a format. Specify a reserved character at least one.
*6 The number of "<DATA1>" and "<DATA2>" that can be set in the format is one for each.
*7 A reserved word quoted with double quotes (") is added as a string to the folder name. A double quote (") itself is not added to the folder
Description
Select this to add the characters specified for each setting folder to the folder name.
Select this to add a date to a folder name.
Year-month-day (YYYYMMDD) is added.
Select this to add a time to a folder name.
Hour-minute-second (hhmmss) is added.
Select this to add a sequential numbers to folder names.
A sequential number corresponding to the saved folder sequential number (00000001 to
FFFFFF01) are added.
Specify the output format of the information to be added to a folder name. (Up to 48
characters) (Page 341 File name and folder (directory) name)
A date and time, and data can be added to the folder name by specifying the following
reserved words.
YYYY: Year (4 digits)
YY
: Year (2 digits)
MM : Month (2 digits)
DD
: Day (2 digits)
ddd : Day of the week
hh
: Hour (2 digits)
mm : Minute (2 digits)
ss
: Second (2 digits)
SNUM: Sequential number (8 digits)
<DATA1>:Content of data set to <DATA1>
<DATA2>:Content of data set to <DATA2>
*9*10
Data
Select this to add a data to a folder name.
Adds "<DATA1>" and "<DATA2>" to the end of the format.
Data name
Displays the data name set to "<DATA1>" and "<DATA2>."
Click the [...] button and set it on the displayed "Data setting" screen.
Page 112 Data setting
Displays the output image of the folder name in a current format.
2 HIGH SPEED DATA LOGGER MODULE CONFIGURATION TOOL
*4
*6*7
*8
(3 digits)
*11
167