Current value layout
Configure the layout settings of the current value to be output to the report.
Window
To add new layout, select "Current value" on the "Layout setting" screen, and click the [Add] button.
Displayed items
Item
Layout name
Cell range
button
(Input assistance button)
Number of pieces of data
Data name
*1
Access target CPU
*1
Device
Head
Last
*1*2
Data type
*1*3
Size
Scaling
Outputting direction
[Import] button
[Relation release] button
*1 These items cannot be edited for related data.
*2 When the data type is string, characters outside the Unicode Basic Multilingual Plane are output by replacing with period (.).
If a string terminator (0) is used halfway in the data, the data is output without replacing a string terminator (0) with period (.), and the
subsequent data is not output.
*3 When using the string type data, specify the size considering the character code. (Page 24 String type data)
Description
Enter the name of the layout. (Up to 32 characters)
Specify the range of cells to output the current value.
Can also be set with the input assistance button.
Click to select the range of cells with the mouse.
Specify the number of consecutive devices to allocate within the cell range.
The amount of data specified here is output in the order specified for output direction.
Displays the start device.
For related data, an icon (
) is displayed.
Select the access target CPU.
To add an access target CPU, select "(Add CPU)" and click the [...] button.
Page 133 Access target CPU setting
Set the start device.
Displays the last device calculated from the number of pieces of data, data type, and size.
Select the data type.
If the data type is "String" or "Raw", the size must be specified.
Set the scale conversion equation for data.
The "Scaling" screen is displayed by clicking the [...] button.
Page 152 Scaling
Select the direction to output the records having current value.
Imports global labels or device comments.
Page 115 Importing global labels
Page 122 Importing common device comments
Disables relations with global labels.
Page 120 Release relations to global labels