Automated System Recovery (ASR) Agent — see Table 4-26 for ASR
Agent settings.
3 Click Apply.
4 Click the appropriate button to continue. See Table 4-27.
Table 4-20. Local Configuration
Setting
Disable the iDRAC
Local Configuration
using option ROM
Disable the iDRAC
Local Configuration
using RACADM
Table 4-21. Web Server Settings
Setting
Enabled
Max Sessions
Active Sessions
Timeout
74
Configuring the iDRAC6 Using the Web Interface
Description
Disables local configuration of iDRAC using option ROM.
Option ROM resides in the BIOS and provides a user
interface engine that allows BMC and iDRAC
configuration. The option ROM prompts you to enter the
setup module by pressing <Ctrl+E>.
Disables local configuration of iDRAC using local
RACADM.
Description
Enables or disables the iDRAC6 Web server. When
checked, the checkbox indicates that the Web server is
enabled. The default is enabled.
The maximum number of simultaneous Web server
sessions allowed for this system. This field is not editable.
The maximum number of simultaneous sessions is five.
The number of current sessions on the system, less than or
equal to the value for Max Sessions. This field is not editable.
The time, in seconds, that a connection is allowed to
remain idle. The session is cancelled when the timeout is
reached. Changes to the timeout setting take affect
immediately and terminate the current Web interface
session. The Web server will also be reset. Please wait for a
few minutes before opening a new Web interface session.
The timeout range is 60 to 10800 seconds. The default is
1800 seconds.