Output; Examples; Sslcsrgen; Synopsis - Dell Remote Access Controller 4 Firmware Version 1.30 User Manual

Remote access controller 4 firmware version 1.30
Table of Contents

Advertisement

Table A-33. setrac Subcommand Options (continued)
-T
Gets the OS type from the managed system and writes it to the DRAC 4. This parameter
is available for viewing using the getsysinfo command and under the object ID interface
using config/getconfig as [ifcRacManagedNodeOs] ifcRacMnOsOsType.
-d
The -d, or display option, allows the user to get the Hostname, OS name, and OS type
from the managed system and display these items only. Parameters are not written to the
DRAC 4. If the -d option is typed along with other options, then those parameters are
displayed only.

Output

A message is displayed indicating the values obtained from the managed system, and if they are
being written to the DRAC 4 or only displayed.

Examples

racadm setrac -d — Only the parameter values are displayed.
racadm setrac -h — The UTC time and managed system name are taken from the managed
system and written to the DRAC 4.

sslcsrgen

NOTE:
Table A-34 describes the sslcsrgen subcommand.
Table A-34. sslcsrgen
Subcommand
sslcsrgen

Synopsis

racadm sslcsrgen [-g] [-u] [-f < filename >]
racadm sslcsrgen -s

Description

The sslcsrgen subcommand is used to generate the CSR and download it to a file, <filename>.
174
racadm Subcommand Man Pages
To use this command, you must have Configure DRAC 4 permission.
Description
Generates and downloads the SSL CSR.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drac 4

Table of Contents